Proceedings of the IEEE · 1967 · 71 citations · 21 references
EngineeringElectrical EngineeringPhysicsElectromagnetismInstrumentationMetrologyElectric FieldsElectrical MeasurementElectromagnetic CompatibilityFrequency MetrologyField Instrument CalibrationHigh-frequency Electromagnetic FieldsMagnetic Field Strength
A description is given of the CW field-strength and associated measurement instrumentation and techniques used for the calibration of both commercial and military field-strength meters in various frequency bands of the overall range from 30 Hz to 1000 MHz, which have been developed at the National Bureau of Standards during the past 25 to 30 years. The techniques are applicable only for evaluating the strength of steady-state, ac fields varying sinusoidally in time, and are not intended for use in broad-band applications of any kind. Two principal types of field-strength standards and a prototype near-zone field-strength meter are described: 1) magnetic-field-strength standards (30 Hz to 30 MHz), 2) electric-field-strength standards (30 to 1000 MHz), and 3) near-zone electric-field-strength meter and interim field-strength standards (150 kHz to 30 MHz).
21
Electromagnetic Waves and Radiating Systems
Edward C. Jordan, C. L. Andrews · American Journal of Physics · 1951 · 1.2K citations
Students Quarterly Journal · 1953 · 714 citations
Electromagnetic waves and radiating systems
S. Charp · Journal of the Franklin Institute · 1951 · 595 citations
Transmission-line Conversion Transformers