Capacitive Micromachined Ultrasonic Transducers for Therapeutic Ultrasound Applications

Serena H. Wong, Mario Kupnik, Ronald D. Watkins, B.T. Khuri-Yakub

IEEE Transactions on Biomedical Engineering · 2009 · 86 citations · 59 references

DOIFull text

Open access

Concepts

TL;DR

Therapeutic ultrasound guided by MRI offers a noninvasive, cost‑effective treatment that can reduce mortality and broaden patient access, and recent advances in capacitive micromachined ultrasonic transducer (CMUT) design have made them competitive with piezoelectric transducers for such applications. This paper presents the first designs and prototypes of an eight‑element, concentric‑ring CMUT array aimed at treating upper abdominal cancers. The authors designed and fabricated an eight‑element concentric‑ring CMUT array, simulating a 30–50 mm focal depth and 680 W cm⁻² intensity at 35 mm, and verified the cell models with 2.5 mm × 2.5 mm test transducers before assembling a full array—though only the four central elements were electronically driven because of yield limitations. The test transducers achieved 2.5 MHz operation with 1.4 MPa peak‑to‑peak output, while the fabricated array’s measured beamwidth matched simulation within 10 % but exhibited doubled sidelobes and a reduced gain of 16.6 versus the simulated 27.4.

Abstract

Therapeutic ultrasound guided by MRI is a noninvasive treatment that potentially reduces mortality, lowers medical costs, and widens accessibility of treatments for patients. Recent developments in the design and fabrication of capacitive micromachined ultrasonic transducers (CMUTs) have made them competitive with piezoelectric transducers for use in therapeutic ultrasound applications. In this paper, we present the first designs and prototypes of an eight-element, concentric-ring, CMUT array to treat upper abdominal cancers. This array was simulated and designed to focus 30-50 mm into tissue, and ablate a 2- to 3-cm-diameter tumor within 1 h. Assuming a surface acoustic output pressure of 1 MPa peak-to-peak (8.5 W/cm (2)) at 2.5 MHz, we simulated an array that produced a focal intensity of 680 W/cm (2) when focusing to 35 mm. CMUT cells were then designed to meet these frequency and surface acoustic intensity specifications. These cell designs were fabricated as 2.5 mm x 2.5 mm test transducers and used to verify our models. The test transducers were shown to operate at 2.5 MHz with an output pressure of 1.4 MPa peak-to-peak (16.3 W/cm (2)). With this CMUT cell design, we fabricated a full eight-element array. Due to yield issues, we only developed electronics to focus the four center elements of the array. The beam profile of the measured array deviated from the simulated one because of the crosstalk effects; the beamwidth matched within 10% and sidelobes increased by two times, which caused the measured gain to be 16.6 compared to 27.4.

References

59