Capacitive micromachined ultrasonic transducers for chemical detection in nitrogen
91
Citations
9
References
2007
Year
Biomedical SensorsEngineeringSensorsMicrofabricationChemical SensorsSensor ApplicationsPolyethylene GlycolTransducer PrincipleMicromachined Ultrasonic TransducerUltrasonic Transducer ArrayBiomedical EngineeringSensor DesignInstrumentationUltrasoundOscillation FrequenciesAcoustic SensorSensor TechnologyChemical Detection
The authors present the prototype of a chemical sensor using a capacitive micromachined ultrasonic transducer array. Each element in the array consists of a large number of resonating membranes connected in parallel. A five-channel oscillator circuit operates at the resonant frequency around 6MHz in this prototype. The surface of the elements in the array is coated by polymers such as polyallylamine hydrochloride, polyethylene glycol, and polyvinyl alcohol to detect different chemicals. By measuring shift in oscillation frequencies due to the mass-loading effect, analytes, e.g., water and isopropanol, with concentrations around 20ppbv (parts per 109 by volume) range can be detected.