Journal of Clinical Microbiology · 1998 · 16 citations · 7 references
Life SciencesInfectious DiseasesMicrobiologyAntimicrobial ResistanceDiagnostic MicrobiologyMedical MicrobiologyAntibiotic ResistanceAntimicrobial Resistance ControlAntimicrobial Resistance PreventionAntimicrobial Susceptibility TestingMicrobiological QualityResistance In Gram-positive BacteriaAntimicrobial Resistance MonitoringClinical Quality MeasuresControl Measures EvaluationMicrobial Susceptibility TestingPathogen Resistance TestingPseudomonas Aeruginosa ResistanceQuality Control In Susceptibility Testing
False results showing an outbreak of Pseudomonas aeruginosa with resistance to imipenem were traced to a defective lot of microdilution MIC testing panels. These panels contained two- to threefold lower concentrations of imipenem than expected and resulted in artifactual two- to fourfold increases in MICs of imipenem. The quality-control MIC results for Pseudomonas aeruginosa ATCC 27853 were 4 microg/ml, the highest value within the range recommended by the National Committee for Clinical Laboratory Standards. We recommend that this value be considered out of the quality-control range.
7
Roger L. White, Meg Kays, Lawrence V. Friedrich et al. · Journal of Clinical Microbiology · 1991 · 40 citations · Full text