IEEE Transactions on Power Electronics · 2013 · 35 citations · 16 references
EngineeringElectrical EngineeringElectric MachinesMotor ControlSensorsDrive SystemsElectric Motor Drive SystemsElectric Motor DrivesPermanent Magnet MachinesStepper MotorsSynchronous MachinesHybrid Stepper MotorsPermanent Magnet Stepper MotorsPermanent Magnet Synchronous MachinesPermanent Magnet Synchronous MotorsRotor Position EstimationStepper MachinesStepper Motor ControlTransient States
Sensorless control of permanent magnet synchronous machines (PMSM) down to zero speed using high-frequency (HF) signal injection is an established method. Stable operation during transient states still presents a challenge for this method, especially for motors with very small anisotropies. This paper introduces a new method for stabilizing the sensorless control scheme. It is shown that a misalignment between the estimated dq coordinate system and the actual rotor position causes a variation of the high-frequency current amplitude. Calculated values based on theoretical observation are compared to actual measurements of a hybrid stepper motor used as a PMSM. Several issues that can be used to determine if a motor is suitable for this approach are addressed. Finally, the effectiveness of the new control scheme is validated by implementation in the existing sensorless control of a hybrid stepper motor.
16
Shunsuke Ichikawa, M. Tomita, Shinji Doki et al. · IEEE Transactions on Industrial Electronics · 2006 · 378 citations · Full text
Engineering, Electrical Engineering, Mechatronics Engineering +17