IEEE Journal of Solid-State Circuits · 2009 · 103 citations · 26 references
EngineeringElectrical EngineeringInstrumentationMetrologyOptoelectronicsDetector TechnologyDigital Signal ProcessingOptical DetectorsOptical MetrologyPhotodetectorsReceiver SystemsDynamic RangeLaser Range FindingLaser Rangefinder MeasurementLaser RangefindersReceiver ArchitectureReceiver DesignTime Interval MeasurementTiming Resolution
The receiver uses a leading‑edge discriminator to generate a stop mark for a TDC, which measures the time interval and slew‑rate between start and stop pulses to correct discriminator walk, all implemented on a 1.3 mm × 1.3 mm die. The integrated receiver achieves 250 ps single‑shot precision, ±37 ps accuracy with walk‑error compensation over a 1:10,000 dynamic range, and consumes less than 45 mW.
An integrated receiver that includes both the time-to-digital converter (TDC) and the receiver channel and is intended for a pulsed time-of-flight laser rangefinder with a measurement range of approximately 10 m has been designed and fabricated in a standard 0.13 mum CMOS process. The receiver operates by detecting the current pulse of an optical detector and producing a stop timing mark for the TDC by means of a leading edge timing discriminator. The TDC is used to measure the actual time interval between the start and stop pulses and the slew-rate of the stop pulse, to compensate for a walk error produced in the discriminator. The single-shot precision of the whole receiver is 250 ps for a minimum detectable signal, and its accuracy and power consumption are plusmn 37 ps with compensation within a dynamic range of at least 1:10,000 and less than 45 mW, respectively. The size of the die is 1300 mum times1300 mum including pads.
26
Ronald Nutt · Review of Scientific Instruments · 1968 · 171 citations