European Journal of Cardio-Thoracic Surgery · 1999 · 61 citations · 18 references
MedicineSurgeryCardiothoracic SurgeryReconstructive SurgeryVascular SurgeryAortic DiseaseAortic ImagingAortic SurgeryAcute Aortic DissectionAortic Arch SurgeryDeep Hypothermic Circulatory ArrestOpen Aortic RepairOpen Aortic SurgeryPostoperative Aortic ImagingType A Aortic Dissection
OBJECTIVE: To compare three different techniques of distal aortic repair in acute type A (de Bakey type I) aortic dissection and to evaluate their impact on the late morphology of the aortic arch and descending aorta and on the incidence of reoperation. METHODS: From 65 patients operated on due to an acute type A aortic dissection between 1989 and 1993, 54 long-term survivors underwent clinical and radiologic follow-up examination after a mean postoperative interval of 62+/-16 months. The surgical techniques of distal aortic reconstruction included closed repair using Teflon felt reinforcement under moderate hypothermic cardiopulmonary bypass (n = 20) and open repair in deep hypothermic circulatory arrest using either Teflon felt reinforcement (n = 16) or gelatin-resorcin-formaldehyde (GRF) glue (n = 18) to readapt the dissected aortic layers. In all patients, MR imaging was performed on a 1.5-T whole body imaging system for the evaluation of the morphology and function of the heart, aorta and supraaortic branches. RESULTS: Overall hospital mortality following surgical repair of type A aortic dissection was 15.4% during this time period. The highest rate of persistent false lumen perfusion (17/20, 85%) and presence of an intimal flap in the aortic arch (13/20, 65%) was observed in patients following closed repair of acute ascending aortic dissection, whereas the lowest rate of such findings was demonstrated in patients who had undergone open distal aortic repair using biological glue (false lumen perfusion 10/18, 55% and intimal flap in the arch 2/18, 11%). Redo-surgery was significantly reduced in the open repair group using GRF glue (1/18, 5.5%) as compared with the Teflon felt repair group (3/16, 18%) and the closed repair group (6/20, 30%). CONCLUSIONS: In patients with acute type A dissection, open distal aortic repair using GRF-glue favourably influences both (1) the severity of late morphologic alterations in the downstream aorta and (2) the incidence of reoperation.
18
Raimund Erbel, H. Oelert, J. Meyer et al. · Circulation · 1993 · 408 citations
Medicine, Cardiology, Surgery +16
Surgery for acute dissection of ascending aorta. Should the arch be included?
E. Stanley Crawford, John W. Kirklin, David C. Naftel et al. · PubMed · 1992 · 230 citations
Medicine, Cardiology, Surgery +17
Significance of distal false lumen after type A dissection repair
Robert A. Phillips, Jan D. Galla, Steven Lansman et al. · The Annals of Thoracic Surgery · 1994 · 197 citations
Surgery for acute dissection of ascending aorta
E. Stanley Crawford, John W. Kirklin, David C. Naftel et al. · Journal of Thoracic and Cardiovascular Surgery · 1992 · 193 citations
Medicine, Cardiology, Surgery +11
Aortic dissection: sensitivity and specificity of MR imaging.
B Kersting-Sommerhoff, C B Higgins, Richard D. White et al. · Radiology · 1988 · 135 citations
Medicine, Cardiology, Radiology +16