IEEE Transactions on Energy Conversion · 2005 · 170 citations · 10 references
EngineeringElectrical EngineeringElectrochemical EngineeringEnergy ManagementEnergy SystemsEnergy Management StrategiesEnergy Management SystemsFuel CellsFuel ManagementPower Plant Control SystemsPower Plant OperationFuel Cell SystemsFuel Utilization EfficiencyHydrogen FuelHydrogen Fuel CellsSolid Oxide Fuel CellsTerminal Voltage ControlTerminal Voltage VariationVoltage Control
The concept of a feasible operating area for a solid oxide fuel-cell power plant is introduced by establishing the relationship between the stack terminal voltage, fuel utilization, and stack current. The analysis shows that both the terminal voltage and the utilization factor cannot be kept constant simultaneously when the stack current changes. This leads to the two possible control strategies as constant utilization control and constant voltage control. By controlling the input hydrogen fuel in proportion to the stack current, constant utilization control can be accomplished. By incorporating an additional external voltage-control loop, stack terminal voltage can be maintained constant. The detailed design of the control schemes is described. The effectiveness of the proposed schemes is illustrated through simulation. Using the numerical results, the maximum value of load power change that the plant can handle safely is predicted.
10
Power electronics converters, applications and design
F.V.P. Robinson · Microelectronics Journal · 1997 · 5.1K citations
Feedback control of dynamic systems
Stephen Kahne · Automatica · 1987 · 3.5K citations