Magnetic Resonance in Medicine · 2007 · 847 citations · 33 references
MedicineBiomedical EngineeringRadiologyBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyBrain ImagingImage ReconstructionImagingMagnetic Resonance Image ReconstructionMagnetic Resonance ImagingMedical ImagingAnalytical ReconstructionGround-truth ValidationHigh Angular Resolution Diffusion ImagingImage Reconstruction AlgorithmsOrientation Distribution FunctionsRegularizationRegularized ReconstructionSimplification
The authors propose a regularized, fast, and robust analytical solution for Q‑ball imaging reconstruction of the orientation distribution function, accompanied by detailed validation and a discussion of its advantages over current methods. The method models the high‑angular‑resolution diffusion signal with a spherical harmonic basis and a Laplace–Beltrami regularization term, yielding a simplified Funk–Radon transform via a new corollary of the Funk–Hecke theorem and is validated against synthetic and real data. Laplace–Beltrami regularization reduces ODF estimation errors, improves fiber detection and angular accuracy, and the technique recovers known fiber crossings while being up to 15 times faster than the original numerical QBI approach. Published in Magn Reson Med 58:497–510, 2007; © 2007 Wiley‑Liss, Inc.
Abstract We propose a regularized, fast, and robust analytical solution for the Q‐ball imaging (QBI) reconstruction of the orientation distribution function (ODF) together with its detailed validation and a discussion on its benefits over the state‐of‐the‐art. Our analytical solution is achieved by modeling the raw high angular resolution diffusion imaging signal with a spherical harmonic basis that incorporates a regularization term based on the Laplace–Beltrami operator defined on the unit sphere. This leads to an elegant mathematical simplification of the Funk–Radon transform which approximates the ODF. We prove a new corollary of the Funk–Hecke theorem to obtain this simplification. Then, we show that the Laplace–Beltrami regularization is theoretically and practically better than Tikhonov regularization. At the cost of slightly reducing angular resolution, the Laplace–Beltrami regularization reduces ODF estimation errors and improves fiber detection while reducing angular error in the ODF maxima detected. Finally, a careful quantitative validation is performed against ground truth from synthetic data and against real data from a biological phantom and a human brain dataset. We show that our technique is also able to recover known fiber crossings in the human brain and provides the practical advantage of being up to 15 times faster than original numerical QBI method. Magn Reson Med 58:497–510, 2007. © 2007 Wiley‐Liss, Inc.
33
Denis Le Bihan, D Lallemand, P. Grenier et al. · Radiology · 1986 · 3.9K citations
David S. Tuch · Magnetic Resonance in Medicine · 2004 · 1.9K citations
Medicine, Neuroscience, Radiology +17