Publication | Open Access
Flow Cytometry for the Detection of Enterohaemorrhagic <i>Escherichia coli</i> O157 : H7 with Latex Beads Sensitized with Specific Antibody
15
Citations
26
References
2000
Year
To detect low concentrations of enterohaemorrhagic Escherichia coli O157:H7 rapidly, flow cytometry (FCM) was carried out with specific IgG-sensitized latex beads (IgG-Lx). It was found that test samples for FCM can be prepared for much shorter periods by culturing E. coli O157:H7 in trypto-soya broth at 42 degrees C and by treatment with 0.5% formalin at 37 degrees C. FCM with IgG-Lx performed with E. coli O157:H7 prepared by such a procedure revealed that the lowest number of E. coli O157:H7 prepared in pure culture detected by FCM was 10(3)/ml. Because similar findings have already been reported by FCM with immunomagnetic beads, FCM with IgG-Lx is also suggested to be a valuable technique to detect low numbers of E. coli O157:H7 rapidly in food stuffs.
| Year | Citations | |
|---|---|---|
Page 1
Page 1