IEEE Transactions on Dielectrics and Electrical Insulation · 2002 · 32 citations · 14 references
Natural SciencesElectrical EngineeringPhysicsElectrochemistrySurface EngineeringSurface ScienceCurrent DistributionSurface ChargeBreakdown VoltageDirect Current DischargesElectrode Effects On BreakdownElectrode GeometryElectrode Geometry EffectsElectrode Tip GeometryStreamer DischargesStreamer Formation
For pt. I see ibid., vol. 9, no. 1, p. 84-91 (2002). Presents a study of streamer inception in transformer oil, in a "semiuniform" geometry under impulse voltage. This geometry consists of parallel plane electrodes, with a thin triggering point of calibrated size emerging at the center of one plane. By reducing the length of the point, it is possible to move progressively from a point-plane geometry, up to a quasi-uniform geometry. Compared to a point-plane gap, the initiation of streamers is impeded due to the presence of a metallic plane behind the triggering point, that reduces the tip field. Field calculations allow to extrapolate the results obtained to the case of microscopic surface protrusions and particles. It is possible to predict the streamer initiation voltage, and hence the breakdown voltage under uniform field, from the shape of the protrusion and from streamer initiation fields measured in point-plane geometry.
14
Properties of the tip-plane configuration
R. Coelho, J. Debeau · Journal of Physics D Applied Physics · 1971 · 213 citations
A unified boundary-element finite-element package
Peter Levin, Andrew J. Hansen, D. Beatovic et al. · IEEE Transactions on Electrical Insulation · 1993 · 68 citations