IEEE Transactions on Energy Conversion · 1988 · 18 citations · 7 references
EngineeringElectrical EngineeringElectric MachinesPower ElectronicsRenewable Energy SystemsDirect Current MachinesElectric DrivesElectric Motor Drive SystemsElectric Motor DrivesElectric MotorsInduction MachinesInduction Motor DrivesInduction MotorsInrush CurrentInrush Current MitigationPhase Angle
A computer model capable of simulating multiple induction motors during bus transfer is described and its results compared with field tests. Optimum switching times are specified based on bus residual voltage and phase angle that will maintain motor inrush currents below ANSI/NEMA criteria. Recent papers have documented the inadequacy of the ANSI/NEMA resultant V/Hz criteria for assuring that motor-shaft torques remain below acceptable levels following bus transfer. The presented results support these findings, but indicate that the combination of high and low-inertia motors fed from the same bus will reduce motor peak-shaft torques when compared to individual transfer of low-inertia motor/pump units alone.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">></ETX>
7
The concept of in-phase transfer applied to industrial systems serving essential service motors
C. C. Young, J. R. Dunki-Jacobs · Transactions of the American Institute of Electrical Engineers Part II Applications and Industry · 1961 · 26 citations
Engineering, Electrical Engineering, Industrial Engineering +9