2002 · 24 citations · 7 references
EngineeringElectrical EngineeringDynamic CapabilitiesElectric MachinesPower ElectronicsAdaptive ControlElectric DrivesElectric Motor DrivesElectric MotorsElectromagnetic InductionInduction MachinesDc-link Voltage ControlDynamic QualitiesField WeakeningInduction Motor DrivesInduction MotorsMachine ModelMagnetic FluxTorque
Quality and reliability of field oriented controlled induction machines depend strongly on the capability of the inverter switching strategy to control the current space phasor according to the desired torque value. Especially at high speed when DC-link voltage is fully utilized the rotor flux level has to be chosen carefully to enable sufficient dynamic qualities of the drive. The paper presents optimal speed and load dependent amplitudes of the rotor flux to achieve constant dynamic behaviour. A combination of an adaptive machine model with a rotor flux controller ensures excellent flux management even during rapid acceleration in the field weakening area. The advantageous function of the scheme is illustrated by experimental results.
7