Journal of Magnetic Resonance Imaging · 2013 · 32 citations · 17 references
MedicineRadiologyBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyBreast Cancer ImagingBreast ImagingBreast Lesion CharacterizationMagnetic Resonance ImagingMagnetic Resonance Imaging PhysicsMedical ImagingContrast-enhanced AngiographyContrast-enhanced Magnetic Resonance AngiographyFourier TransformLesion Enhancement KineticsLesion VisualizationMagnetic Resonance AngiographyMagnetic Resonance Imaging Lesion EvaluationSignal Enhancement
PURPOSE: To evaluate a magnetic resonance imaging (MRI) technique that integrates time-resolved angiography with stochastic trajectories (TWIST) view sharing and Dixon for a breast dynamic contrast-enhanced (DCE)-MRI application. MATERIALS AND METHODS: Simulation study: K-space data at six timepoints (1 pre-, 5 postcontrast) were generated by performing Fourier transform on a digital "phantom" with 3-9 mm enhancing lesions and three types of enhancement curves (persistent, plateau, washout). Images were reconstructed with and without TWIST. Clinical study: Six TWIST-Dixon image sets (one pre-, five postcontrast) were acquired in 18 patients on a 3T scanner, followed by one conventional image set. The last TWIST-Dixon and the conventional images were scored for seven criteria: perceived signal-to-noise ratio (P.SNR), visualization of anatomy, fat suppression (FS) accuracy, FS uniformity, ghosting artifact, edge ringing artifact, and overall image quality (IQ). RESULTS: Simulation study: With proper TWIST parameters (pA ≥33%, pB ≥50%), the enhancement underestimation was 5% or less for tumor size ≥5 mm. Clinical study: TWIST-Dixon images have significantly better scores in all criteria except for ghosting artifacts, where the difference was not significant. CONCLUSION: With proper parameters, TWIST-Dixon provides higher perceived SNR, more accurate fat suppression, and better overall image quality for breast DCE-MRI without sacrificing accuracy in the enhancement estimation.
17
Simple proton spectroscopic imaging.
W. Thomas Dixon · Radiology · 1984 · 2.3K citations
Abdominal MR Imaging with a Volumetric Interpolated Breath-hold Examination
Neil M. Rofsky, Vivian S. Lee, Gerhard Laub et al. · Radiology · 1999 · 536 citations
Diagnostic Architectural and Dynamic Features at Breast MR Imaging: Multicenter Study
Mitchell D. Schnall, Jeffrey D. Blume, David A. Bluemke et al. · Radiology · 2006 · 511 citations
Matthias P. Lichy, Beate Wietek, John P. Mugler et al. · Investigative Radiology · 2005 · 189 citations
Manojkumar Saranathan, Dan Rettmann, Brian A. Hargreaves et al. · Journal of Magnetic Resonance Imaging · 2012 · 147 citations