Magnetic Resonance Imaging of the Body Trunk Using a Single-Slab, 3-Dimensional, T2-weighted Turbo-Spin-Echo Sequence With High Sampling Efficiency (SPACE) for High Spatial Resolution Imaging

Matthias P. Lichy, Beate Wietek, John P. Mugler, Wilhelm Horger, Marion I. Menzel, Aristotelis G. Anastasiadis, K Siegmann, Thomas Niemeyer, A. Königsrainer, Berthold Kiefer,

Investigative Radiology · 2005 · 189 citations · 19 references

Concepts

Abstract

PURPOSE: The authors conducted a clinical evaluation of single-slab, 3-dimensional, T2-weighted turbo-spin-echo (TSE) with high sampling efficiency (SPACE) for high isotropic body imaging with large field-of-view (FoV). MATERIALS AND METHODS: Fifty patients were examined in clinical routine with SPACE (regions of interest: pelvis n=30, lower spine n=12, upper spine n=6, extremities n=4) at 1.5 T. For achieving a high sampling efficiency, parallel imaging, high turbofactor, and magnetization restore pulses were used. In contrast to a conventional TSE imaging technique with constant flip angle refocusing, the refocusing pulse train of the SPACE sequence consists of variable flip angle radiofrequency pulses along the echo train. RESULTS: Signal-to-noise ratio and contrast-to-noise ratio of SPACE images were of sufficient diagnostic value. The possibility of image reconstruction in multiple planes was of clinical relevance in all cases and simplified data analysis. CONCLUSION: The achievement of 3-dimensional, T2-weighted TSE magnetic resonance imaging with isotropic and high spatial resolution and interactive 3-dimensional visualization essentially improve the diagnostic potential of magnetic resonance imaging.