Bioanalysis · 2014 · 12 citations · 10 references
PharmacyPharmaceutical AnalysisClinical BiochemistryMass Spectrometric AnalysisTherapeutic Drug MonitoringBioanalytical Method ValidationChromatographyClinical AnalysisLiquid ChromatographyAccuracyAnalytical AccuracyLinear RangeProtein PrecipitationQuantitative Assay ValidationSerum Drug Concentration MeasurementSerum Therapeutic Drug Monitoring
BACKGROUND: Monitoring lacosamide (LCM) helps optimize therapeutic dosing in some clinical settings. We developed a novel LC-MS/MS method for measuring serum LCM and O-desmethyl lacosamide (ODL). RESULTS/DISCUSSION: The sample preparation was protein precipitation with methanol. The total CV was less than 4.7%. Calibration range was 0.95-30.29 µg/ml and 0.95-30.41 µg/ml while the expanded linear range was 0.41-47.49 µg/ml and 0.34-48.17 µg/ml for LCM and ODL, respectively with analytical accuracy of 87.2-106.0%. 45 random serum samples collected from 23 individuals on either 200 mg/day or 400 mg/day of LCM therapy showed concentrations of 2.2-19.8 µg/ml for LCM and up to 2.5 µg/ml for ODL. CONCLUSION: A simple and sensitive LC-MS/MS assay was validated for quantification of LCM and ODL in human serum.
10
Therapeutic Drug Monitoring of the Newer Anti-Epilepsy Medications
Matthew D. Krasowski · Pharmaceuticals · 2010 · 123 citations · Full text
François‐Ludovic Sauvage, Jean‐Michel Gaulier, Gérard Lachâtre et al. · Clinical Chemistry · 2008 · 104 citations · Full text
Examining the Clinical Utility of Lacosamide
Steve Chung, Elinor Ben‐Menachem, Michael R. Sperling et al. · CNS Drugs · 2010 · 85 citations
Joachim Kühn, Cornelius Knabbe · Talanta · 2013 · 58 citations