PharmacyPharmaceutical AnalysisPharmacologyAnalytical ChemistryAnalytical ToxicologyMass Spectrometric AnalysisChromatographyInstrumental AnalysisMetabolite IdentificationMetabolite QuantificationToxicological Drug ScreeningToxicological Screening Of PharmaceuticalsFalse-positive ResultsLiquid Chromatography-mass Spectrometry AnalysisMass Spectrometric Drug AnalysisMass Spectrometric ScreeningMultiple Reaction MonitoringSelected Reaction MonitoringStable Isotope StandardsTandem Mass Spectrometry Analysis
BACKGROUND: We observed cases of false-positive results with the use of liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS). Different LC-MS/MS techniques that use the selected reaction-monitoring mode, routinely employed for the analysis and quantification of drugs and toxic compounds in biological matrices, were involved in the false-positive and potentially false-positive results obtained. We sought to analyze the causes of and solutions to this problem. METHODS: We used a previously reported LC-MS/MS general unknown screening method, as well as manual spectral investigation in 1 case, to perform verification and identification of interfering compounds. RESULTS: We observed that false-positive results involved: a metabolite of zolpidem that might have been mistaken for lysergic acid diethylamide, benzoylecgonine mistaken for atropine, and clomipramine and 3 phenothiazines that share several common ion transitions. CONCLUSIONS: To prevent problems such as those we experienced, we recommend the use of stable-isotope internal standards when possible, relative retention times, 2 transitions or more per compound when possible, and acceptable relative abundance ratios between transitions, with an experience-based tolerance of +/-15% for transitions with a relative abundance >10% and with an extension to +/-25% for transitions <10% when the concentration is at the limit of quantification. A powerful general unknown screening procedure can help to confirm suspected interferences. Our results indicate that the specificity of screening procedures is questionable for LC-MS/MS analyses performed in the selected reaction-monitoring mode and involving a large number of compounds with only 1 transition per compound.
22
Bioanalytical Method Validation—A Revisit with a Decade of Progress
Vinod P. Shah, Kamal K. Midha, John W. A. Findlay et al. · Pharmaceutical Research · 2000 · 1.6K citations
Hartmut Kirchherr, W. Nikolaus Kühn‐Velten · Journal of Chromatography B · 2006 · 357 citations
Christoph Mueller, Wolfgang Weinmann, Sebastian Dresen et al. · Rapid Communications in Mass Spectrometry · 2005 · 239 citations