Design and optimization of microring resonators in biochemical sensing applications

Chung-Yen Chao, L. Jay Guo

Journal of Lightwave Technology · 2006 · 271 citations · 18 references

Concepts

Abstract

Microring resonators can be exploited for biochemical sensing applications. To gain a better understanding of the design and optimization of microring sensors, the authors analytically derive the detection limit and the sensitivity. Other important parameters, including the ON-OFF contrast ratio and the signal-to-noise ratio (SNR), are also considered. In this paper, the combination of two sensing mechanisms and two sensing schemes are analyzed. These calculations provide a guideline for determining the microring geometry to satisfy the desired sensing requirements. In addition, the results can provide insights on how to enhance the sensitivity and lower the detection limit.

References

18