Vascular Surgery · 1987 · 12 citations · 1 references
MedicineSurgeryVeterinary SurgeryBiocompatibilityBiomaterialsVascular SurgeryCardiovascular BiomaterialsConnective TissueVascular TissueBypass Graft MaterialsConnective Tissue ResponseExperimental CharacterizationReactivitySuture Material PropertiesTissue Damage ResponseVascular GraftingVascularization Of Grafted Tissue
Three currently available cardiovascular suture materials (braided dacron, polypropylene, PTFE) were compared in a series of abdominal aortic grafting in the beagle dog, aiming at the definition of tissue response. Optimal accept ance by tissues was demonstrated for monofilaments (PTFE, polypropylene); braided dacron was shown to cause a heavy and prolonged tissue reaction.