Optics Letters · 2001 · 94 citations · 16 references
EngineeringBiomedical EngineeringBiophysicsBiomedical OpticsBiophotonicsOpticsAbsorption In TissueOptical ImagingReflectance ModelingScattering In TissueTissue Optical PropertiesTissue OpticsAbsorption CoefficientsDiffusion EquationOptical Characterization Of Biological TissueOptical PropertiesOptical Properties EstimationPhase FunctionReflectanceTissue Absorption Coefficients
Spatially resolved reflectance measurements are widely used for determination of the optical properties of biological media. However, the influence of the phase function on these measurements has not been quantified. We show that errors in the derived reduced scattering and absorption coefficients are as great as 100% for both absolute and relative spatially resolved reflectance measurements if a standard solution of the diffusion equation is used in the analysis. In addition, we investigated nonlinear regressions, using Monte Carlo simulations and an additional fitting parameter that characterizes the phase function, and found that the errors in the obtained optical coefficients were </=20% .
16
Thomas J. Farrell, Michael S. Patterson, Brian C. Wilson · Medical Physics · 1992 · 1.4K citations
Light scattering in lntralipid-10% in the wavelength range of 400–1100 nm
Hugo J. van Staveren, Christian J. M. Moes, Jan van Marie et al. · Applied Optics · 1991 · 1.1K citations
Alwin Kienle, Lothar Lilge, Michael S. Patterson et al. · Applied Optics · 1996 · 498 citations