American Journal of Neuroradiology · 2010 · 518 citations · 19 references
MedicineNeurosurgerySurgeryCerebrovascular NeurosurgeryCerebrovascular SurgeryVascular SurgeryAneurysm RepairAneurysm SurgeryCarotid Artery SurgeryCerebrovascular DiseaseAneurysm Sac ThrombosisCerebral Aneurysm RuptureRemodelingStent-assisted Aneurysm TreatmentThrombosis Pathophysiology
BACKGROUND AND PURPOSE: FD technology enables reconstructive repair of otherwise difficult-to-treat intracranial aneurysms. These stentlike devices may induce progressive aneurysm thrombosis without additional implants and may initiate complete reverse vessel remodeling. The associated vascular biologic processes are as yet only partially understood. MATERIALS AND METHODS: From 12 different centers, 13 cases of delayed postprocedural aneurysm rupture were recorded and analyzed. Symptom, aneurysm location and morphology, and the time elapsed from treatment until rupture were analyzed. RESULTS: There were 10 internal carotid and 3 basilar artery aneurysms. Mean aneurysm diameter was 22 ± 6 mm. Eleven patients were symptomatic before treatment. A single FD was used for all saccular aneurysms, while fusiform lesions were treated by using multiple devices. A supplementary loose coiling of the aneurysm was performed in 1 patient only. Ten patients developed early aneurysm rupture after FD treatment (mean, 16 days; range, 2-48 days); in 3 patients, rupture occurred 3-5 months after treatment. In all cases, most of the aneurysm cavity was thrombosed before rupture. The biologic mechanisms predisposing to rupture under these conditions are reviewed and discussed CONCLUSIONS: FDs alone may modify hemodynamics in ways that induce extensive aneurysm thrombosis. Under specific conditions, however, instead of reverse remodeling and cicatrization, aggressive thrombus-associated autolysis of the aneurysm wall may result in delayed rupture.
19
Hemodynamic Shear Stress and Its Role in Atherosclerosis
Adel M. Malek · JAMA · 1999 · 3.6K citations
CURATIVE ENDOVASCULAR RECONSTRUCTION OF CEREBRAL ANEURYSMS WITH THE PIPELINE EMBOLIZATION DEVICE
Pedro Lylyk, Carlos Miranda, Rosana Ceratto et al. · Neurosurgery · 2009 · 803 citations
Medicine, Neurosurgery, Surgery +14
Remodeling of Saccular Cerebral Artery Aneurysm Wall Is Associated With Rupture
Juhana Frösén, Anna Piippo, Anders Paetau et al. · Stroke · 2004 · 733 citations
István Szikora, Zsolt Berentei, Zsolt Kulcsár et al. · American Journal of Neuroradiology · 2010 · 565 citations · Full text
Medicine, Neurosurgery, Surgery +12