On-line failure detection in nuclear power plant instrumentation

J. Louis Tylee

IEEE Transactions on Automatic Control · 1983 · 77 citations · 4 references

Concepts

TL;DR

The authors propose and evaluate a functional redundancy approach for detecting instrument failures in nuclear power plant instrumentation, applied to a pressurized water reactor pressurizer. The method employs a bank of Kalman filters—one per instrument—to generate optimal state estimates, and identifies failures through consistency checks between filter outputs. Real‑time pressurizer data confirm that the functional redundancy technique can detect instrument failures effectively.

Abstract

The functional redundancy approach to detecting instrument failures in nuclear power plant instrumentation is described and evaluated. This real-time method uses a bank of Kalman filters (one for each instrument) to generate optimal estimates of the plant state. By performing consistency checks between the output of each filter, failed instruments can be identified. The technique is used to design an instrument failure detection system for a pressurized water reactor (PWR) pressurizer. Actual pressurizer data are used to demonstrate the capabilities of the functional redundancy methods.