IEEE Transactions on Nuclear Science · 2005 · 27 citations · 6 references
EngineeringMaterials EngineeringMaterials ScienceElectronic MaterialsRadiation DetectionSpectroscopyDetector TechnologyGamma-ray DetectionGamma-ray DetectorsGamma-ray SpectroscopyRadiation DetectorsSemiconductor DetectorsAnode DesignCompensation TechniquesDetector Energy ResolutionDetector FabricationDetectorsSemiconductor Gamma-ray DetectorsSpectral CharacteristicsTemperature Effects
The results of our newest depth sensing coplanar grid CdZnTe detectors will be discussed. These detectors, which utilize the third-generation coplanar anode design, were fabricated by Baltic Scientific Instruments, Ltd., using crystals acquired from Yinnel Tech, Inc., having dimensions of 1.5 cm /spl times/1.5cm/spl times/ 0.9 cm and 1.5 cm /spl times/ 1.5cm /spl times/ 0.95 cm. Employing various compensation techniques, an energy resolution of about 1.7% full width at half maximum (FWHM) was achieved for 662-keV gamma rays. We observed that the spectral performance was highly dependent upon the biasing orientation of the detector. The /spl mu//sub e//spl tau//sub e/ product for one of the crystals was measured and it was found to be a high value of 1.13 /spl times/ 10/sup -2/ cm/sup 2//V. A study of the spectroscopic performance of CdZnTe for reduced temperature operation was implemented and we observed degraded performance for temperatures below 0/spl deg/C and a complete loss of spectral information at -30/spl deg/C.
6
Zhong He, G.F. Knoll, D.K. Wehe · Journal of Applied Physics · 1998 · 77 citations · Full text