Medical Physics · 2008 · 127 citations · 32 references
MedicineRadiologySurgeryBiomedical ImagingDiagnostic ImagingTreatment PlanningComputed TomographyImage RegistrationMedical ImagingRadiographic ImagingThree-dimensional ReconstructionVolume Registration3D Image RegistrationMedical Image RegistrationPatient-to-image RegistrationRegistrationSimilarity MeasuresThree-dimensional Image ReconstructionThree-dimensional Image RegistrationTransformations In Coordinate Plane
The authors developed a fast and accurate two-dimensional (2D)-three-dimensional (3D) image registration method to perform precise initial patient setup and frequent detection and correction for patient movement during image-guided cranial radiosurgery treatment. In this method, an approximate geometric relationship is first established to decompose a 3D rigid transformation in the 3D patient coordinate into in-plane transformations and out-of-plane rotations in two orthogonal 2D projections. Digitally reconstructed radiographs are generated offline from a preoperative computed tomography volume prior to treatment and used as the reference for patient position. A multiphase framework is designed to register the digitally reconstructed radiographs with the x-ray images periodically acquired during patient setup and treatment. The registration in each projection is performed independently; the results in the two projections are then combined and converted to a 3D rigid transformation by 2D-3D geometric backprojection. The in-plane transformation and the out-of-plane rotation are estimated using different search methods, including multiresolution matching, steepest descent minimization, and one-dimensional search. Two similarity measures, optimized pattern intensity and sum of squared difference, are applied at different registration phases to optimize accuracy and computation speed. Various experiments on an anthropomorphic head-and-neck phantom showed that, using fiducial registration as a gold standard, the registration errors were 0.33 +/- 0.16 mm (s.d.) in overall translation and 0.29 degrees +/- 0.11 degrees (s.d.) in overall rotation. The total targeting errors were 0.34 +/- 0.16 mm (s.d.), 0.40 +/- 0.2 mm (s.d.), and 0.51 +/- 0.26 mm (s.d.) for the targets at the distances of 2, 6, and 10 cm from the rotation center, respectively. The computation time was less than 3 s on a computer with an Intel Pentium 3.0 GHz dual processor.
32
Image-guided Robotic Radiosurgery
John R. Adler, Martin J. Murphy, Steven Hancock · Neurosurgery · 1999 · 416 citations
Medicine, Neurosurgery, Surgery +17
Image‐guided and intensity‐modulated radiosurgery for patients with spinal metastasis
Samuel Ryu, F Yin, Jack Rock et al. · Cancer · 2003 · 333 citations