Sensors · 2013 · 10 citations · 28 references
MedicineComputer ScienceRadiologyComputer VisionDiagnostic ImagingEarly DetectionBreast ImagingCancer DetectionCancer Early DetectionComputer-aided DiagnosisEarly Cancer DetectionMedical Image AnalysisAutomated Feature EngineeringAutomated Feature RecognitionBreast Microcalcification AnalysisFeature Set OptimizationFree ResponseScreening MammographySequential Backward SelectionSequential Forward Selection
We propose a fully automated algorithm that is able to select a discriminative feature set from a training database via sequential forward selection (SFS), sequential backward selection (SBS), and F-score methods. We applied this scheme to microcalcifications cluster (MCC) detection in digital mammograms for early breast cancer detection. The system was able to select features fully automatically, regardless of the input training mammograms used. We tested the proposed scheme using a database of 111 clinical mammograms containing 1,050 microcalcifications (MCs). The accuracy of the system was examined via a free response receiver operating characteristic (fROC) curve of the test dataset. The system performance for MC identifications was Az = 0.9897, the sensitivity was 92%, and 0.65 false positives (FPs) were generated per image for MCC detection.
28
A Study of Cross-Validation and Bootstrap for Accuracy Estimation and Model Selection
Ron Kohavi · 1995 · 10.7K citations · Full text
A support vector machine approach for detection of microcalcifications
I. El-Naqa, Yongyi Yang, M.N. Wernick et al. · IEEE Transactions on Medical Imaging · 2002 · 574 citations