Quantification of Hordeins by ELISA: The Correct Standard Makes a Magnitude of Difference

54

Citations

50

References

2013

Year

Abstract

Accurate determination of hordein requires that the hordein standard used to calibrate the ELISA reaction be identical in composition to the hordeins present in the test substance. In practice it is not feasible to isolate a representative hordein standard from each test food. We suggest that mass spectrometry is more reliable than ELISA, as ELISA enumerates only the concentration of particular amino-acid epitopes which may vary between different hordeins and may not be related to the absolute hordein concentration. MS quantification is undertaken using peptides that are specific and unique enabling the quantification of individual hordein isoforms.