Circulation Arrhythmia and Electrophysiology · 2013 · 137 citations · 24 references
MedicineCardiologySurgeryCerebrovascular SurgeryInterventional CardiologyNeuroradiologyAblation TherapyAtrial FibrillationCatheter AblationCerebrovascular DiseaseStrokeThrombosisActivated Clotting TimeAtrial Fibrillation ImagingAtrial Fibrillation-related ThromboembolismMultielectrode Array TechnologyNeurological FunctionSheath Insertion TechniqueSurgical AblationVitamin K Antagonist Therapy
BACKGROUND: This prospective, multicenter study sought to evaluate the incidence of asymptomatic cerebral emboli (ACE) during ablation of atrial fibrillation (AF) using a multielectrode radiofrequency (MER) system when specific procedural changes were applied. METHODS AND RESULTS: Sixty subjects (age 60±10 years; 87% paroxysmal; CHADS2 score, 0.6±0.7) undergoing AF ablation with a circular MER catheter were studied. Three procedural changes were specified: (1) ablation was performed under therapeutic vitamin K antagonist and heparin to maintain activated clotting time>350 seconds; (2) submerged loading of the catheter into the introducer before sheath insertion to minimize air ingress; and (3) either the distal or proximal electrode of the circular MER catheter was deactivated to prevent inadvertent bipolar radiofrequency interaction. MRI was performed <7 days preablation and 2 days postablation. Subjects with new cerebral findings after ablation underwent repeat MRI after 1 month. An acute ACE lesion was defined by a new hyperintensity on diffusion-weighted and fluid-attenuated inversion recovery cerebral MRI sequences. Neurological function was evaluated at baseline, postablation, and 1 month. All target pulmonary veins were isolated. In 60% (36/60) of patients, pre-existing cerebral lesions were seen on the preprocedure MRI (8 lesions per subject; interquartile range, 3-22). New postprocedural ACE occurred in only 1/60 patients (incidence, 1.7%; 95% confidence interval, 0.04-8.9), which was no longer visible on MRI after 1 month. CONCLUSIONS: Applying procedural changes to MER ablation significantly reduces the ACE incidence to 1.7%, which is on the low end of reported ACE rates of any technology. CLINICAL TRIAL REGISTRATION INFORMATION: ClinicalTrials.gov; Identifier: NCT01520532.
24
Karl Heinz Kuck, Riccardo Cappato, Josép Brugada et al. · EP Europace · 2012 · 2.7K citations · Full text
Medicine, Cardiology, Surgery +11
Hugh Calkins, Riccardo Cappato, Josép Brugada et al. · Heart Rhythm · 2012 · 1.5K citations · Full text
Medicine, Cardiology, Surgery +17
Radiofrequency Catheter Ablation of Atrial Fibrillation: A Cause of Silent Thromboembolism?
Fiorenzo Gaïta, Domenico Caponi, Martina Pianelli et al. · Circulation · 2010 · 358 citations · Full text
Medicine, Cardiology, Surgery +17
Fiorenzo Gaïta, Jean Leclercq, Burghard Schumacher et al. · Journal of Cardiovascular Electrophysiology · 2011 · 285 citations · Full text
Medicine, Cardiology, Surgery +15