IEEE Transactions on Medical Imaging · 2002 · 70 citations · 15 references
ComputingComputer ScienceOphthalmologyClinical Vision ScienceComputer VisionOcular Imaging3D Imaging3D ReconstructionDepth EstimationRetinal DisparityStereo VisionThree-dimensional ReconstructionDepth From DisparityDigital Image AnalysisDisparity ComputationDisparity EstimationDisparity Map EstimationOptic Nerve Head EvaluationStereo Image Pair GenerationStereo Imaging
The major limitations of precise evaluation of retinal structures in present clinical situations are the lack of standardization, the inherent subjectivity involved in the interpretation of retinal images, and intra- as well as interobserver variability. While evaluating optic disc deformation in glaucoma, these limitations could be overcome by using advanced digital image analysis techniques to generate precise metrics from stereo optic disc image pairs. A digital stereovision system for visualizing the topography of the optic nerve head from stereo optic disc images is presented. We have developed an algorithm, combining power cepstrum and zero-mean-normalized cross correlation techniques, which extracts depth information using coarse-to-fine disparity between corresponding windows in a stereo pair. The gray level encoded sparse disparity matrix is subjected to a cubic B-spline operation to generate smooth representations of the optic cup/disc surfaces and new three-dimensional (3-D) metrics from isodisparity contours. Despite the challenges involved in 3-D surface recovery, the robustness of our algorithm in finding disparities within the constraints used has been validated using stereo pairs with known disparities. In a preliminary longitudinal study of glaucoma patients, a strong correlation is found between the computer-generated quantitative cup/disc volume metrics and manual metrics commonly used in a clinic. The computer generated new metrics, however, eliminate the subjective variability and greatly reduce the time and cost involved in manual metric generation in follow-up studies of glaucoma.
15
David Huang, Eric A. Swanson, Charles P. Lin et al. · Science · 1991 · 13.7K citations
Optical Coherence Tomography of the Human Retina
Michael R. Hee · Archives of Ophthalmology · 1995 · 1.6K citations
Variability of expert observers in evaluating the optic disc.
Paul R. Lichter · PubMed · 1976 · 307 citations · Full text
Medicine, Optometry, Vision Science +12
Intraobserver and Interobserver Agreement in Measurement of Optic Disc Characteristics
James M. Tielsch, Joanne Katz, Harry A. Quigley et al. · Ophthalmology · 1988 · 283 citations