Medical Engineering & Physics · 2011 · 47 citations · 22 references
MedicineSurgeryVeterinary SurgeryBiocompatibilitySurgical InstrumentationAbdominal AnatomyAbdominal SurgeryAbdominal Wall ReconstructionImplant BiomechanicsRabbit AnatomyRabbit SurgeryAbdominal Wall AssessmentAbdominal Wall ClosureAbdominal Wall Defect ClosureAbdominal Wall Hernia RepairBiomechanical Testing Of ImplantsBiomechanics Of The Abdomen
BACKGROUND: An ideal prosthetic mesh for incisional hernia repair should mimic the anisotropic compliance of the abdominal wall, and at lower loads should exhibit higher distensibility without impairment of safety at higher loads. This study evaluated the biomechanical properties of six meshes in a rabbit model. METHODS: New Zealand white rabbits were used for this study. Two meshes of the same brand (Ethicon Physiomesh™, Bard Composix(®) L/P, Gore Dualmesh(®), Bard Sepramesh(®), Ethicon Proceed(®) or Parietex™ Composite) were implanted into each animal for assessment of intra-abdominal hernia repair, with a total of ten meshes per group. Twelve weeks after implantation, the abdominal walls with ingrown meshes were harvested and examined biomechanically with a plunger test. The mesh-tissue compliance was evaluated by the forces exerted at given displacements and also described through a simple mathematical approximation. Abdominal wall samples were collected for histopathology, cell turnover and morphometry. RESULTS: No mesh-related complications were seen. The adhesion score was significantly higher in Bard Composix(®) L/P and Ethicon Proceed(®) meshes. Significant shrinkage was seen in Gore Dualmesh(®) and Parietex™ Composite meshes. Physiomesh™ exhibited the highest compliance during plunger testing, characterized by lower, more physiological reaction forces against tissue displacement than the competitor meshes. In contrast, the safety modulus was comparable in all groups. Histology showed less collagen and less foreign body reaction in the Physiomesh™ samples contributing to patient's comfort. CONCLUSION: In terms of safety, this study showed no superiority of any single mesh. The comfort modulus however differed, being lowest in the newly developed Physiomesh™.
22
Use of marlex mesh in the repair of incisional hernias.
Usher Fc, John L. Ochsner, Tuttle Ll · PubMed · 1958 · 311 citations
Medicine, Surgery, General Surgery +10
K. Junge, U. Klinge, A. Prescher et al. · Hernia · 2001 · 273 citations
Eelco B. Wassenaar, Ernst J. P. Schoenmaeckers, J.T. Raymakers et al. · Surgical Endoscopy · 2009 · 180 citations · Full text
Medicine, Surgery, Pain Management +13
Polypropylene in the intra-abdominal position: Influence of pore size and surface area
J. Conze, R. Rösch, U. Klinge et al. · Hernia · 2004 · 136 citations