Proteome Analysis of Maternal Serum Samples for Trisomy 21 Pregnancies Using ProteinChip Arrays and Bioinformatics

Anne Busch, Susanne Michel, Constance Hoppe, Dominik Driesch, Uwe Claussen, Ferdinand von Eggeling

Journal of Histochemistry & Cytochemistry · 2005 · 28 citations · 10 references

DOIFull text

Open access

Concepts

Abstract

A surface-enhanced laser desorption/ionization time of flight (SELDI-TOF)-based ProteinChip System was used as a tool for rapid discovery and identification of protein patterns in serum that discriminate between trisomy 21 and unaffected pregnancies. We analyzed 24 serum samples from women carrying a trisomy 21 pregnancy and 32 with an unaffected pregnancy, ranging from 10.0 to 14.0 weeks of gestation. The resulting protein profiles were submitted to a clustering algorithm, a rule extraction, a rating, and a rule base construction step. For the generated combined rule base, the specificity and sensitivity for the prediction of a trisomy 21 pregnancy reach 97% and 91%, respectively.

References

10