Respiratory Care · 2011 · 46 citations · 11 references
Health ProfessionsClinical SciencesRespiratory TherapyPulmonologyVentilationVentilator ManagementMechanical VentilationMechanical Ventilation ModesPatient-ventilator SynchronyPressure Support VentilationVentilator ModesVentilatory SupportAirway Pressure MonitoringEsophageal Pressure MeasurementFlow-triggered VentilationMechanical Ventilator TriggeringPressure DropTriggering AsynchronyVentilator AsynchronyVentilator-induced Asynchrony
BACKGROUND: Double-triggering (DT) is a frequent type of patient-ventilator asynchrony and has potentially severe consequences, such as alveolar overdistention or the generation of intrinsic PEEP. However, the first breath of DT could be patient-triggered (DT-P), auto-triggered (DT-A), or ventilator-triggered (DT-V). OBJECTIVE: To differentiate DT-P, DT-A, and DT-V using airway pressure or flow changes during the trigger-delay phase in ventilated patients. METHODS: Fourteen mechanically ventilated patients with DT were included. All patients were on flow-triggered ventilation modes and received either continuous mandatory ventilation or pressure support ventilation. Breaths in which the first breath was associated with an esophageal pressure drop of > 1 cm H(2)O were categorized as DT-P. Breaths in which the first breath occurred at the ventilator set cycle were categorized as DT-V. Breaths in which the first breath occurred earlier than the ventilator set cycle without esophageal pressure drop were categorized as DT-A. The pressure drop and flow change at 0.13 s (PD(0.13) and F(0.13), respectively) in the trigger-delay phase were calculated from the nadir. RESULTS: There were 507 double-triggered breaths: 271 DT-V (53%), 50 DT-A (10%), and 186 DT-P (37%). The PD(0.13) for DT-V, DT-A, and DT-P were 0.16 ± 0.12 cm H(2)O, 0.25 ± 0.17 cm H(2)O, and 1.34 ± 0.67 cm H(2)O, respectively. The F(0.13) for DT-V, DT-A, and DT-P were 2.11 ± 2.31 L/min, 2.64 ± 2.07 L/min, and 16.51 ± 8.02 L/min, respectively. The best discriminatory criteria for differentiating DT-P from DT-V and DT-A, based on the Youden index (sensitivity + specificity - 1) was PD(0.13) ≥ 0.49 cm H(2)O, which had a Youden index of 95%. CONCLUSION: DT-P can be distinguished from DT-V and DT-A by using airway pressure deflections in the trigger-delay phase.
11
A simple method for assessing the validity of the esophageal balloon technique.
Ahmet Baydur, P. K. Behrakis, Walter A. Zin et al. · PubMed · 1982 · 1.1K citations
Patient-ventilator asynchrony during assisted mechanical ventilation
Arnaud W. Thille, Pablo Rodríguez, Belén Cabello et al. · Intensive Care Medicine · 2006 · 923 citations · Full text
Francesco Fanfulla, Monica Delmastro, Angela Berardinelli et al. · American Journal of Respiratory and Critical Care Medicine · 2005 · 182 citations