Applied Optics · 2006 · 326 citations · 18 references
EngineeringBiomedical EngineeringBiophysicsBiomedical ImagingBiomedical OpticsBiophotonicsAbsorption In TissueLight-tissue InteractionReflectance ModelingScattering In TissueTissue Optical PropertiesTissue OpticsMie ScatteringOptical Characterization Of Biological TissueOptical PropertiesReduced Scattering CoefficientReflectanceScatteringScattering CoefficientsTissue Scattering Coefficients
A flexible and fast Monte Carlo-based model of diffuse reflectance has been developed for the extraction of the absorption and scattering properties of turbid media, such as human tissues. This method is valid for a wide range of optical properties and is easily adaptable to existing probe geometries, provided a single phantom calibration measurement is made. A condensed Monte Carlo method was used to speed up the forward simulations. This model was validated by use of two sets of liquid-tissue phantoms containing Nigrosin or hemoglobin as absorbers and polystyrene spheres as scatterers. The phantoms had a wide range of absorption (0-20 cm(-1)) and reduced scattering coefficients (7-33 cm(-1)). Mie theory and a spectrophotometer were used to determine the absorption and reduced scattering coefficients of the phantoms. The diffuse reflectance spectra of the phantoms were measured over a wavelength range of 350-850 nm. It was found that optical properties could be extracted from the experimentally measured diffuse reflectance spectra with an average error of 3% or less for phantoms containing hemoglobin and 12% or less for phantoms containing Nigrosin.
18
Thomas J. Farrell, Michael S. Patterson, Brian C. Wilson · Medical Physics · 1992 · 1.4K citations
Diffuse reflectance spectroscopy of human adenomatous colon polyps in vivo
George Zonios, Lev T. Perelman, Vadim Backman et al. · Applied Optics · 1999 · 535 citations
Differential Light Scattering from Spherical Mammalian Cells
A. Brunsting, P. F. Mullaney · Biophysical Journal · 1974 · 253 citations · Full text