American Journal of Neuroradiology · 2014 · 146 citations · 24 references
MedicineNeurosurgerySurgeryBiomaterialsCerebrovascular SurgeryVascular SurgeryAneurysm RepairAneurysm SurgeryAneurysm RetreatmentAneurysm Sac OcclusionCerebral Aneurysm RuptureClinical Failure CriteriaNoninferiority TestingNoninferiority Trial PowerNoninferiority Trial Sample SizeNoninferiority Trials
BACKGROUND AND PURPOSE: The ability of polymer-modified coils to promote stable aneurysm occlusion after endovascular treatment is not well-documented. Angiographic aneurysm recurrence is widely used as a surrogate for treatment failure, but studies documenting the correlation of angiographic recurrence with clinical failure are limited. This trial compares the effectiveness of Matrix(2) polyglycolic/polylactic acid biopolymer-modified coils with bare metal coils and correlates the angiographic findings with clinical failure (ie, target aneurysm recurrence), a composite end point that includes any incident of posttreatment aneurysm rupture, retreatment, or unexplained death. MATERIALS AND METHODS: This was a multicenter randomized noninferiority trial with blinded end point adjudication. We enrolled 626 patients, divided between Matrix(2) and bare metal coil groups. The primary outcome was target aneurysm recurrence at 12 ± 3 months. RESULTS: At 455 days, at least 1 target aneurysm recurrence event had occurred in 14.6% of patients treated with bare metal coils and 13.3% of Matrix(2) (P = .76, log-rank test) patients; 92.8% of target aneurysm recurrence events were re-interventions for aneurysms that had not bled after treatment, and 5.8% of target aneurysm recurrence events resulted from hemorrhage or rehemorrhage, with or without retreatment. Symptomatic re-intervention occurred in only 4 (0.6%) patients. At 455 days, 95.8% of patients with unruptured aneurysms and 90.4% of those with ruptured aneurysms were independent (mRS ≤ 2). Target aneurysm recurrence was associated with incomplete initial angiographic aneurysm obliteration, presentation with rupture, and a larger aneurysmal dome and neck size. CONCLUSIONS: Tested Matrix(2) coils were not inferior to bare metal coils. Endovascular coiling of intracranial aneurysms was safe, and the rate of technical success was high. Target aneurysm recurrence is a promising clinical outcome measure that correlates well with established angiographic measurements.
24
Andrew Molyneux, Richard Kerr, Ly‐Mee Yu et al. · The Lancet · 2005 · 2.9K citations
Medicine, Neurosurgery, Surgery +17
Jean Raymond, F Guilbert, Alain Weill et al. · Stroke · 2003 · 1.5K citations · Full text
Medicine, Neurosurgery, Surgery +9
Andrew Molyneux, Richard Kerr, Jacqueline Birks et al. · The Lancet Neurology · 2009 · 906 citations · Full text
Medicine, Neurosurgery, Surgery +17
The Barrow Ruptured Aneurysm Trial
Cameron G. McDougall, Robert F. Spetzler, Joseph M. Zabramski et al. · Journal of neurosurgery · 2011 · 641 citations