Optical Engineering · 1998 · 92 citations · 0 references
Natural SciencesPhysicsOpticsGeometric CorrectionInfrared InstrumentationInfrared TelescopesMeasurement ErrorPhysical OpticsAberration CorrectionsFocal Plane ArraysInfrared ArraysInfrared Detector ArraysNonlinearity CorrectionNonuniformity CorrectionPositional Measurement ErrorsStandard Errors Of Measurement
The error and hence the residual nonuniformity in an IR focal plane array, after two-point linear nonuniformity correction, which results from measurement errors and nonlinearity, is calculated, yielding different results than have been obtained in the past.