PLoS ONE · 2010 · 158 citations · 56 references
In this study we demonstrate that it is possible to monitor the metabolic activity, morphology, ECM production and oxidative stress of hMSCs in a non-invasive manner. This is accomplished using generally available multiphoton microscopy equipment and simple data analysis techniques, such that the method can widely adopted by laboratories with a diversity of comparable equipment. This method therefore represents a powerful tool, which enables researchers to monitor engineered tissues and optimize culture conditions in a near real time manner.
56
Two-Photon Laser Scanning Fluorescence Microscopy
Winfried Denk, James H. Strickler, Watt W. Webb · Science · 1990 · 9.3K citations