CORROSION · 1999 · 120 citations · 4 references
Natural SciencesMaterials EngineeringMaterials ScienceCorrosion ScienceElectrochemical EngineeringElectrochemistryCorrosion EngineeringCorrosion MechanismsCorrosion Of SteelsCorrosion TestingElectrochemical CorrosionLocalized CorrosionCorrosion Mechanism AnalysisElectrochemical Corrosion TestingElectrochemical MeasurementsElectrochemical NoiseElectrochemical Noise AnalysisLocalised CorrosionLocalized Corrosion AssessmentRoot-mean-square Deviation
The localization index (LI), which is defined as the ratio of the standard deviation and the root square mean (rms) of current fluctuation determined in electrochemical noise measurements, can have values between 0 and 1. It has been proposed in the literature that the LI can be used to determine the nature of the prevailing corrosion mechanism with values of 1 being characteristic of localized corrosion. Experimental data for mild steel in sodium chloride (NaCl) have produced LI values close to 0, while the LI for a Ti alloy in Ringer's solution was found to be close to 1. It was concluded that the LI should be considered as a measure of the deviation from the assumed identical behavior of the two test electrodes and not as an indicator of corrosion mechanisms.
4
Analysis of electrochemical impedance and noise data for polymer coated metals
F. Mansfeld, C.C. Lee, Chider Chen et al. · Corrosion Science · 1997 · 112 citations
Natural Sciences, Materials Engineering, Materials Science +14