EuroIntervention · 2009 · 63 citations · 14 references
MedicineCardiologyRadiologyBiomedical ImagingInterventional CardiologyUltrasonographyInterventional UltrasoundIntracoronary ImagingIntravascular ImagingStent PlacementVascular UltrasoundBackscatteringNecrotic Core CharacterizationNecrotic MorphologyStent Placement ImagingTemporal Changes In DensityTissue Composition AnalysisTissue Composition EstimationVirtual Histology
AIMS: The main objective was to use IVUS-backscatter radiofrequency (IVUS-RF) to assess the degradation of a bioabsorbable stent by measuring serial changes in dense calcium (DC) and necrotic core (NC) as assessed by intravascular ultrasound-Virtual Histology (IVUS-VH) and in the strain as assessed by palpography. METHODS AND RESULTS: In the ABSORB trial, 27 patients treated with a single bioabsorbable everolimus-eluting stent (BVS, Abbott Vascular, Santa Clara, CA, USA) were all imaged with IVUS-RF post-stenting and at 6-month follow-up, and 13 and 12 patients were also investigated pre-stenting with IVUS-VH and palpography respectively. From pre- to post-stenting, with VH (n = 13), there was an increase in mean "DC" (9.8 vs. 25.4%, p = 0.0002) and "NC" (15.5 vs. 30.5%, p = 0.0002). In palpography (n = 12), the mean number of frames with Rotterdam Classification (ROC) III/IV per cm decreased from 1.22 +/- 1.91 to 0.12 +/- 0.31 (p = 0.0781) and the mean cumulative strain values (all frames with ROC I-IV scores) changed from 0.50 +/- 0.27 to 0.20 +/- 0.10% (p = 0.0034). Comparing post-stenting with follow-up (n = 27), VH showed a decrease in "DC" (29.7% vs. 21.1%, p = 0.0001). "NC" also decreased (26.9 vs. 21.5%, p = 0.0027). For palpography (n = 25 patients), an increase in the mean number of frames with ROC III/IV per cm was observed from 0.09 +/- 0.26 to 0.22 +/- 0.36 (p = -0.1563) while the mean cumulative strain values (all frames with ROC I-IV scores) changed from 0.15 +/- 0.10 to 0.26 +/- 0.12% (p < 0.0001). CONCLUSIONS: IVUS-VH changes at 6 months suggest alteration of the BVS with reduction of RF backscattering by polymeric struts. Strained plaques on the palpograms were almost abolished following stent implantation. However, strain values reappeared within 6 months suggesting an increase in endoluminal deformability of the stented vessel.
14
Safety and Efficacy of Sirolimus- and Paclitaxel-Eluting Coronary Stents
Gregg W. Stone, Jeffrey W. Moses, Stephen G. Ellis et al. · New England Journal of Medicine · 2007 · 1.6K citations · Full text
Late thrombosis in drug-eluting coronary stents after discontinuation of antiplatelet therapy
Eugène McFadden, Eugenio Stabile, Evelyn Regar et al. · The Lancet · 2004 · 1.4K citations
Medicine, Cardiology, Pharmacology +16
Coronary Plaque Classification With Intravascular Ultrasound Radiofrequency Data Analysis
Anuja Nair, Barry D. Kuban, E. Murat Tuzcu et al. · Circulation · 2002 · 1.1K citations · Full text
Medicine, Cardiology, Radiology +17
Initial and 6-Month Results of Biodegradable Poly- <i>l</i> -Lactic Acid Coronary Stents in Humans
Hideo Tamai, Keiji Igaki, Eisho Kyo et al. · Circulation · 2000 · 801 citations