MIMO over‑the‑air test methodology is evolving, with multiple‑probe techniques proposed, and the number of probes needed to synthesize desired fields is a key cost factor. This study reviews prior work and derives guidelines for the number of probes required as a function of test zone size and target field‑synthesis uncertainty. The authors formulate probe‑count rules by modeling the multiprobe system and relating probe number to zone size in wavelengths for specified uncertainty levels.

Abstract

Development of MIMO over-the-air (OTA) test methodology is ongoing. Several test methods have been proposed. Anechoic chamber-based multiple-probe technique is one promising candidate for MIMO-OTA testing. The required number of probes for synthesizing the desired fields inside the multiprobe system is an important issue as it has a large impact on the cost of the test system. In this paper, we review the existing investigations on this important topic and end up presenting rules for the required number of probes as a function of the test zone size in wavelengths for certain chosen uncertainty levels of the field synthesis.