Journal of Physics D Applied Physics · 2000 · 13 citations · 6 references
Natural SciencesPhysicsNuclear PhysicsPlasma PhysicsSpectroscopyCollisions In PlasmasFusion PlasmasLow-temperature PlasmasPlasma DiagnosticsCollisional-radiative ModelingElectron DensityElectron Density DistributionsElectron Density ProfilesLine Emission SpectraPlasma Density ProfilingRadial ProfilesTemperature Profiles
In this paper a method to determine spatially-resolved profiles of the electron temperature Teand density nein an electron-cyclotron-resonance (ECR) discharge is presented. This technique is based on the observation of line emission from a neutral Li atom beam, which is injected into the plasma and excited by electron collisions. A collisional-radiative model valid for the injected Li atoms is used to predict the emission intensities as function of neand Tefor several lines theoretically. In contrast to the electron temperature regime representative for the edge of tokamak discharges (Te >5 eV), the ECR discharge offers a Terange where selected line intensity ratios strongly depend on the electron temperature. Therefore, a comparison of the measured ratios with the calculated ones yields Teprofiles for the first time. The nemeasurement is performed as in tokamaks by observing the attenuation of the beam due to ionization in the plasma. We present radial profiles of Teand nefor discharges in argon and xenon under different operating conditions. These results are compared with results obtained by Thomson scattering. Our measurements give evidence for a satisfying agreement between the two methods.
6