EngineeringBiotechnologyChemical EngineeringBiochemical EngineeringBioprocess EngineeringBioreactor DesignBioreaction EngineeringEnzyme KineticsEnzyme Reactor DesignMembrane Bioreactor SystemsEnzymatic HydrolysisEnzyme ConcentrationHollow Fiber BioreactorsHollow Fiber MembranesHydrolysisMembrane Enzyme ReactorsMembrane ReactorsProtein Hydrolysate Production
Abstract An Ultrafiltration (UF) based reactor system for continuous hydrolysis of proteins was developed to overcome limitations of the traditional batch process. A continuous stirred tank reactor was coupled to a hollow fiber module in a semiclosed loop configuration. Capacity of the reactor, defined as quantity of hydrolysate produced/time/weight of enzyme, was a sensitive function of enzyme concentration between 55 and 94% substrate conversion levels for the Pronase‐Promine D system. Increasing flow rate also improved capacity, but substrate concentration and reactor volume had small effects on capacity within the levels of expected use. Productivity (defined as weight of hydrolysate/weight of enzyme) was at least 10‐20 times greater for the continuous UF reactor than a batch reactor operating under otherwise identical conditions.
5