Journal of The Electrochemical Society · 1972 · 11 citations · 0 references
Natural SciencesMaterials EngineeringMaterials SciencePhysical ChemistrySurface ScienceThin FilmsChemical Vapor DepositionMetalsSurface OxidationThin Film OxidationChemical Vapor Deposition MaterialsCopper ChemistryDensityGrain DensityOxidation Defect FormationResidual Gas Fraction
(100) copper films were prepared by vapor deposition in the presence of hydrogen, water, or air in the pressure range from 10−8 to 10−4 Torr. The films were annealed and oxidized under constant conditions and were examined at various stages by electron microscopy and diffraction. A reproducible decrease in the grain density was observed when hydrogen was the residual gas: a ten‐fold increase in pH2, in the range between , resulted in a decrease of . The appearance of wide stacking faults in unannealed copper films and the occurrence of oxide grains also was observed.