IEEE Transactions on Applied Superconductivity · 2002 · 42 citations · 4 references
Natural SciencesNuclear EngineeringPhysicsElectromagnetismFusion EngineeringPlasma PhysicsPlasma ConfinementSuperconducting Magnet SystemsSuperconducting MaterialsTokamak EngineeringCyclic Load TransferCyclic LoadingHigh-temperature Superconducting Magnet TechnologyMagnet TestingSuperconducting Cable DesignSuperconducting Magnet Design
Two subsize, Nb/sub 3/Sn cable-in-conduit conductors, are tested as short samples in the SULTAN test facility. Transverse load is applied by sweeping up and down the operating current in high background field. A serious performance loss of I/sub c/ and n-factor is observed upon cyclic load, with a drop of the critical current, I/sub c/, larger than 30%. The results are critically discussed and compared to similar findings from the literature. The impact of the cyclic load on the Nb/sub 3/Sn CICC performance must be carefully evaluated in the magnet design.
4
Upgrade of operating range for SULTAN test facility
P. Bruzzone, A. Anghel, A.M. Fuchs et al. · IEEE Transactions on Applied Superconductivity · 2002 · 141 citations · Full text
First test results for the ITER central solenoid model coil
Takashi Kato, Hiroshi Tsuji, T. Ando et al. · Fusion Engineering and Design · 2001 · 46 citations