Electric Power Components and Systems · 2006 · 25 citations · 15 references
EngineeringElectrical EngineeringElectric MachinesPower ElectronicsRenewable Energy SystemsBrushless Dc MachinesElectric MotorsGenerator OperationInduction MachinesMachine HeatingMachine WindingsCurrent UnbalanceInduction MotorsMotor PerformanceNegative Sequence CurrentsRotor WindingsSquirrel-cage Induction MotorsVoltage UnbalanceWound-rotor Induction Motors
A summary of the literature about the effect of unbalanced supply voltage on induction motors is presented. An experimental study was carried out, where rotor currents of a wound-rotor induction motor were measured under different unbalance conditions with respect to positive and negative sequence voltage magnitudes and phase angles. Rotor overcurrent is not a function of the angle between positive and negative voltage components. Effect of rotor overcurrent is under-estimated by the measured stator overcurrent, and rotor currents are closely similar. The currently used unbalanced-voltage derating factors do not seem to consider rotor winding heating, which is only applicable to squirrel-cage rotors.
15
Assessment of voltage unbalance
Annette von Jouanne, B. Banerjee · IEEE Transactions on Power Delivery · 2001 · 594 citations
Assessment of Voltage Unbalance
Annette von Jouanne, B. Banerjee · IEEE Power Engineering Review · 2001 · 496 citations