Proceedings of the National Academy of Sciences · 1996 · 1.2K citations · 11 references
Natural SciencesBioengineeringBiophysicsBiosensorsMolecular BiophysicsMolecular RecognitionAntibody-antigen RecognitionBiomolecular InteractionsForce SensorsMolecular SensorsProtein-ligand BindingProtein-ligand RecognitionAntibody Binding KineticsAntibody-antigen KineticsAntigen Recognition ForcesAntigen-antibody Binding KineticsAntigen-antibody InteractionsAntigen-antibody RecognitionDissociation Rate ConstantsMolecular Mapping
A force‑microscopy sensor was built by covalently attaching an anti‑human serum albumin antibody to the tip via a flexible spacer, giving the antibody a 6‑nm dynamic reach that yields a 0.5 binding probability over 60 ms and enables fast, reliable detection of antigenic sites with 1.5‑nm positional accuracy. The sensor detects single antibody‑antigen recognition events as distinct force signals with an unbinding force of 244 ± 22 pN, revealing that individual Fab fragments dissociate independently with equal probability, and the method promises kinetic characterization and molecular mapping of biosurfaces.
A methodology has been developed for the study of molecular recognition at the level of single events and for the localization of sites on biosurfaces, in combining force microscopy with molecular recognition by specific ligands. For this goal, a sensor was designed by covalently linking an antibody (anti-human serum albumin, polyclonal) via a flexible spacer to the tip of a force microscope. This sensor permitted detection of single antibody-antigen recognition events by force signals of unique shape with an unbinding force of 244 +/- 22 pN. Analysis revealed that observed unbinding forces originate from the dissociation of individual Fab fragments from a human serum albumin molecule. The two Fab fragments of the antibody were found to bind independently and with equal probability. The flexible linkage provided the antibody with a 6-nm dynamical reach for binding, rendering binding probability high, 0.5 for encounter times of 60 ms. This permitted fast and reliable detection of antigenic sites during lateral scans with a positional accuracy of 1.5 nm. It is indicated that this methodology has promise for characterizing rate constants and kinetics of molecular recognition complexes and for molecular mapping of biosurfaces such as membranes.
11
G. Binnig, C. F. Quate, Ch. Gerber · Physical Review Letters · 1986 · 14.4K citations · Full text
Adhesion Forces Between Individual Ligand-Receptor Pairs
Ernst‐Ludwig Florin, Vincent T. Moy, Hermann E. Gaub · Science · 1994 · 1.9K citations
Imaging Crystals, Polymers, and Processes in Water with the Atomic Force Microscope
B. Drake, Craig Prater, A. L. Weisenhorn et al. · Science · 1989 · 1K citations
Natural Sciences, Chemistry, Physics +12
Direct Measurement of the Forces Between Complementary Strands of DNA
Gil U. Lee, Linda A. Chrisey, Richard J. Colton · Science · 1994 · 764 citations