Journal of Dental Sciences · 2014 · 44 citations · 2 references
DentistryDental HygienePeriodonticsInfection PreventionMedical MicrobiologyOral MicrobiologyBiofilm FormationMicrobiological SamplingOral Bacterial InfectionsOral HygieneOral Hygiene PracticesOral InfectionsAerosol PenetrationBacterial Contamination ControlBacterial Contamination PreventionBiological ContaminantsDental Infection ControlInfection Control MeasuresRiskScaling With Antimicrobials
This study attempted to understand the spreading characteristics of airborne bacterial contaminants during dental scaling treatment. Bacterial aerosols were collected with gelatin filters, in a single-chair clinic during ultrasonic scaling treatments on two patients with periodontitis. The results showed that bacterial aerosols contamination could spread a horizontal distance of 100 cm and a vertical distance of 50 cm from a patient’s oral cavity, and remain airborne suspended for 20 minutes. Proper environmental and personal infection control measures, including isolation, ventilation, and full-cover facial shield, are recommended to diminish the contaminating risk in dental clinics.
2
Atmospheric contamination during ultrasonic scaling
M. F. Timmerman, L. Menso, J. Steinfort et al. · Journal Of Clinical Periodontology · 2004 · 101 citations