Tomographic imaging of two-component flow using capacitance sensors

S.M. Huang, A. Pląskowski, Cheng Xie, M.S. Beck

Journal of Physics E Scientific Instruments · 1989 · 251 citations · 5 references

Concepts

Abstract

Describes a tomographic flow imaging system based on capacitance sensors. It uses eight capacitance electrodes to perform a 'body scan' of the fluid-conveying pipe, and a linear back projection algorithm is developed to reconstruct the cross-sectional image of the two-component flow from the measured capacitance values. A prototype system has been successfully assembled and reconstructed images of static distribution models are presented. Possible industrial applications and practical limitations of the system are discussed.

References

5