PLoS ONE · 2012 · 47 citations · 28 references
MedicineNuclear MedicineRadiologyBiomedical ImagingDiagnostic ImagingDiagnostic Nuclear MedicineNuclear Medicine ImagingRadiotracer TechniquesThyroid ImagingThyroid ScintigraphyThyroid Uptake StudiesIodine-123 ScintigraphyIodine-131 ScintigraphyRadionuclide BiodistributionRadionuclide Thyroid ImagingRadionuclide Uptake QuantificationRadiopharmaceutical UptakeRadiotracer Uptake QuantificationTracer Uptake Quantification
BACKGROUND: Cerenkov luminescence tomography (CLT) provides the three-dimensional (3D) radiopharmaceutical biodistribution in small living animals, which is vital to biomedical imaging. However, existing single-spectral and multispectral methods are not very efficient and effective at reconstructing the distribution of the radionuclide tracer. In this paper, we present a semi-quantitative Cerenkov radiation spectral characteristic-based source reconstruction method named the hybrid spectral CLT, to efficiently reconstruct the radionuclide tracer with both encouraging reconstruction results and less acquisition and image reconstruction time. METHODOLOGY/PRINCIPAL FINDINGS: We constructed the implantation mouse model implanted with a 400 µCi Na(131)I radioactive source and the physiological mouse model received an intravenous tail injection of 400 µCi radiopharmaceutical Iodine-131 (I-131) to validate the performance of the hybrid spectral CLT and compared the reconstruction results, acquisition, and image reconstruction time with that of single-spectral and multispectral CLT. Furthermore, we performed 3D noninvasive monitoring of I-131 uptake in the thyroid and quantified I-131 uptake in vivo using hybrid spectral CLT. Results showed that the reconstruction based on the hybrid spectral CLT was more accurate in localization and quantification than using single-spectral CLT, and was more efficient in the in vivo experiment compared with multispectral CLT. Additionally, 3D visualization of longitudinal observations suggested that the reconstructed energy of I-131 uptake in the thyroid increased with acquisition time and there was a robust correlation between the reconstructed energy versus the gamma ray counts of I-131 (r(2) = 0.8240). The ex vivo biodistribution experiment further confirmed the I-131 uptake in the thyroid for hybrid spectral CLT. CONCLUSIONS/SIGNIFICANCE: Results indicated that hybrid spectral CLT could be potentially used for thyroid imaging to evaluate its function and monitor its treatment for thyroid cancer.
28
Thomas J. Farrell, Michael S. Patterson, Brian C. Wilson · Medical Physics · 1992 · 1.4K citations
<i>Čerenkov Radiation and Its Applications</i>
J. V. Jelley, Sanborn C. Brown · Physics Today · 1959 · 604 citations
George Alexandrakis, Fernando R. Rannou, Arion F. Chatziioannou · Physics in Medicine and Biology · 2005 · 463 citations · Full text