Construction and performance of an x-ray undulator beamline at the TRISTAN Accumulation Ring
27
Citations
2
References
1992
Year
X-ray SpectroscopyNuclear PhysicsEngineeringSynchrotron Radiation SourceSynchrotron Radiation ResearchRadiation GenerationTristan Accumulation RingAccelerator TechnologyPhysicsAtomic PhysicsUndulator X RaysX-ray Undulator BeamlineX-ray Free-electron LaserSynchrotron RadiationParticle Beam PhysicsExperimental Nuclear PhysicsNatural SciencesSpectroscopyX-ray DiffractionApplied PhysicsIn-vacuum Type UndulatorX-ray Optic
An in-vacuum type undulator and its beamline NE3 with a Si(111) double-crystal monochromator is under commissioning. Spectra of synchrotron radiation measured in the energy range of 5–25 keV from the undulator shows a very good agreement with theoretical calculation. Some experiments of resonant nuclear scattering using 57Fe have been carried out using the third harmonics of the spectra. It has been proved that the undulator x rays are quite suitable for experiments of very small scattering cross sections.