2010 · 10 citations · 7 references
EngineeringElectrical EngineeringMaterials ScienceMechanical Behavior Of MaterialsStructural EngineeringStructural MaterialsInsulation MaterialsInsulation SystemsStrength Of MaterialsAxial StrainBow-tie AnalysisCable InsulationCable MaterialsCable StructuresCompressive StrainSimplified ModelsTensile Strain
By bending commercially available XLPE power cables around hollow cylinders with different diameters, the insulation was subjected to a wide range of tensile and compressive strains. By using a simplified model, the applied compressive and tensile axial strains at the conductor screen of the bent cables were estimated to be in the range of 0-18%. Both the density and growth of vented water trees at the conductor screen increased significantly with increasing applied axial tensile strain, and a corresponding reduction was observed for compressive strain. Approximately 98% of the vented trees grew from the conductor screen, probably caused by higher electrical field stress and exposure to lower temperatures during the manufacturing process. The angular distribution of bow-tie trees was similar to the distribution of vented trees.
7
Water Treeing Phenomena in Humid Air
Tetsuo Yoshimitsu, H. Mitsui, Kazuo HISHIDA et al. · IEEE Transactions on Electrical Insulation · 1983 · 12 citations