Earthquake Engineering & Structural Dynamics · 2008 · 169 citations · 6 references
EngineeringCivil EngineeringEarthquake EngineeringSeismic DesignStructural EngineeringEarthquake Response Of StructuresSeismic Design PrinciplesStructural ConnectionsStructural DesignStructural MechanicsStructural SystemsBraced FramesDissipative MechanismsDissipative StructuresDual Structural SystemsEarthquakesGlobal Seismic ResponseSeismic PerformanceSteel Frame Structures
Structural damage in buildings designed with dissipative systems can be significant even under moderate earthquakes, making repair costly and disruptive. The study investigates eccentrically braced frames with removable links bolted to beams as a practical way to isolate damage to removable dissipative members. High‑strength steel is used for members outside the links to constrain plastic deformations to the removable links and reduce permanent drifts, thereby enhancing global seismic performance. Dual configurations comprising a rigid subsystem with removable ductile elements and a flexible subsystem are shown to be suitable for implementing the removable dissipative element concept. © 2008 John Wiley & Sons, Ltd.
Abstract Structural damage in buildings designed according to the dissipative design philosophy can be significant, even under moderate earthquakes. Repair of damaged members is an expensive operation and may affect building use, which in turn increases the overall economic loss. If damage can be isolated to certain dissipative members realized to be removable following an earthquake, the repair costs and time of interruption of building use can be reduced. Dual structural configurations, composed of a rigid subsystem with removable ductile elements and a flexible subsystem, are shown to be appropriate for the application of removable dissipative element concept. Eccentrically braced frames with removable links connected to the beams using flush end‐plate bolted connections are investigated as a practical way of implementing this design concept. High‐strength steel is used for members outside links in order to enhance global seismic performance of the structure by constraining plastic deformations to removable links and reducing permanent drifts of the structure. Copyright © 2008 John Wiley & Sons, Ltd.
6